Achieving sub-1 ppm oxygen in glove box
Sub-1 ppm Oxygen Control System for Glove Boxes
By Burhani Engineering Technology
Burhani Engineering Technology offers a high-performance Oxygen Purification and Control System engineered to achieve and reliably maintain sub-1 ppm oxygen levels within inert atmosphere glove boxes. Designed for precision laboratories and advanced manufacturing environments, the system ensures ultra-low oxygen conditions critical for moisture- and oxygen-sensitive processes.
By combining advanced gas purification technology, leak-tight engineering, and intelligent monitoring, this solution delivers exceptional atmospheric purity, long-term stability, and operational reliability.
Key Features & Benefits
-
Ultra-Low Oxygen Performance
Achieves and sustains oxygen concentration below 1 ppm, even during active glove box operation. -
Advanced Oxygen Removal Technology
High-efficiency getter or catalyst-based oxygen purification system ensures rapid and continuous oxygen scavenging. -
Inert Gas Compatibility
Optimized for use with Nitrogen (N₂), Argon (Ar), and Helium (He) atmospheres. -
Precision Monitoring & Control
Integrated high-accuracy oxygen analyzer with real-time digital display and alarm thresholds. -
Leak-Tight Construction
Engineered sealing and welded stainless-steel gas paths minimize oxygen ingress. -
Low Maintenance Operation
Long-life purifier materials reduce downtime and operating costs. -
Modular & Scalable Design
Suitable for new glove boxes or retrofitting existing systems.
Typical Applications
-
Lithium-ion battery research and production
-
OLED and semiconductor fabrication
-
Pharmaceutical and chemical synthesis
-
Air- and moisture-sensitive material handling
-
Advanced R&D laboratories
Sub-1 ppm Oxygen & Moisture Control System for Glove Boxes
By Burhani Engineering Technology
Burhani Engineering Technology offers an advanced Oxygen and Moisture Purification & Control System designed to achieve and consistently maintain sub-1 ppm levels of both Oxygen (O₂) and Moisture (H₂O) inside inert atmosphere glove boxes. The system is purpose-built for high-precision environments where even trace contamination can compromise product integrity or process reliability.
By integrating high-efficiency purification technology, hermetically sealed gas handling, and precision analytical monitoring, the system ensures long-term atmospheric purity, fast recovery after exposure, and stable performance during continuous operation.
Key Features & Benefits
-
Ultra-Low Oxygen & Moisture Performance
Maintains O₂ < 1 ppm and H₂O < 1 ppm, even during frequent glove use or material transfer.
-
Dual Purification Technology
Combined oxygen getter / catalyst and moisture adsorption (molecular sieve or desiccant) system ensures simultaneous removal of O₂ and H₂O.
-
Rapid Atmosphere Recovery
Fast purification cycle restores sub-ppm conditions after chamber access or sample loading.
-
Inert Gas Compatibility
Designed for Nitrogen (N₂), Argon (Ar), and Helium (He) glove box environments.
-
Precision Monitoring & Alarms
High-accuracy oxygen and moisture analyzers with real-time digital display, programmable alarms, and data output.
-
Leak-Tight & Clean Construction
All-metal gas paths, welded joints, and high-integrity seals minimize contamination ingress.
-
Low Maintenance & Long Service Life
Regenerable purification materials and optimized gas circulation reduce operating cost.
-
Modular & Retrofit-Ready
Compatible with new glove boxes or existing systems requiring performance upgrades.
Ultra-Low Oxygen & Moisture Performance
Maintains O₂ < 1 ppm and H₂O < 1 ppm, even during frequent glove use or material transfer.
Dual Purification Technology
Combined oxygen getter / catalyst and moisture adsorption (molecular sieve or desiccant) system ensures simultaneous removal of O₂ and H₂O.
Rapid Atmosphere Recovery
Fast purification cycle restores sub-ppm conditions after chamber access or sample loading.
Inert Gas Compatibility
Designed for Nitrogen (N₂), Argon (Ar), and Helium (He) glove box environments.
Precision Monitoring & Alarms
High-accuracy oxygen and moisture analyzers with real-time digital display, programmable alarms, and data output.
Leak-Tight & Clean Construction
All-metal gas paths, welded joints, and high-integrity seals minimize contamination ingress.
Low Maintenance & Long Service Life
Regenerable purification materials and optimized gas circulation reduce operating cost.
Modular & Retrofit-Ready
Compatible with new glove boxes or existing systems requiring performance upgrades.
Typical Applications
-
Lithium-ion battery R&D and manufacturing
-
Semiconductor and OLED fabrication
-
Organometallic and air-sensitive chemistry
-
Pharmaceutical formulation and synthesis
-
Advanced materials research laboratories
Lithium-ion battery R&D and manufacturing
Semiconductor and OLED fabrication
Organometallic and air-sensitive chemistry
Pharmaceutical formulation and synthesis
Advanced materials research laboratories
Technical Specifications
| Parameter | Specification |
|---|---|
| Achievable Oxygen Level | < 1 ppm |
| Oxygen Removal Method | Getter-based / Catalyst-based purification |
| Inert Gas Type | N₂, Ar, He |
| Operating Pressure | −5 to +5 mbar (typical glove box range) |
| Gas Flow Rate | Configurable (up to customer requirement) |
| Oxygen Sensor Type | Electrochemical / Zirconia (high accuracy) |
| Measurement Range | 0–1000 ppm |
| Control Interface | Digital display with alarm & data output |
| Construction Material | SS 304 / SS 316 (optional) |
| Operating Temperature | Ambient |
| Power Supply | 230 VAC, 50/60 Hz |
| Download Brochure https://www.bhfvacuum.com/ |


No comments: